Ahonesty

Passive Radiative Cooling Film

Passive Radiative Cooling Film

Passive Radiative Cooling Film is a peel-and-stick thermal-management film for roofs, warehouses and outdoor equipment. Third-party tested solar reflectance: 0.92; emissivity in the 8-13 μm atmospheric window: 0.90; radiative cooling power: 95 W/m².

Contact our technical team for formulation support and sample evaluation.

We welcome global partners, distributors, and project owners to get in touch with us.

Contact Us

Product Overview

Passive Radiative Cooling Film is a peel-and-stick functional film designed to reduce solar heat gain through high solar reflection and efficient thermal emission through the 8-13 μm atmospheric window. It provides electricity-free passive thermal management for roofs, building envelopes and outdoor equipment while supporting waterproofing and surface protection in suitable applications.

The multilayer film combines a weather-resistant hydrophobic surface, functional cooling layer, mechanically stable base film and pressure-sensitive adhesive for fast installation without curing time.

Key Features

  • Verified passive cooling performance: Third-party testing reports solar reflectance of 0.92, atmospheric-window emissivity of 0.90 and radiative cooling power of 95 W/m².
  • Peel-and-stick installation: The self-adhesive roll can be applied directly to properly prepared metal, roofing and equipment surfaces.
  • Weather and corrosion resistance: Tested for 1500 h xenon-lamp aging, 1500 h neutral salt spray and 1500 h damp-heat exposure.
  • Hydrophobic surface: A tested water contact angle of 120° helps reduce water and dirt adhesion.
  • Mechanical integrity: Tested peel strength reached 1.8 N/mm, with transverse and longitudinal tensile strength of 25 MPa and 42 MPa.
  • Cooling plus roof protection: Suitable systems can combine thermal-management and waterproofing value.

Typical Applications

  • Industrial plants, warehouses and logistics centers
  • Grain-storage buildings and agricultural facilities
  • Metal roofs, sandwich panels and building walls
  • Telecom stations and outdoor electrical equipment
  • Petrochemical tanks, silos and equipment enclosures
  • Containers, utility shelters and other sun-exposed surfaces

Third-Party Test Data

Test ItemReported Result
Solar Reflectance0.92
Near-Infrared Reflectance0.95
Emissivity (8-13 μm)0.90
Radiative Cooling Power95 W/m²
Water Contact Angle120°
Peel Strength1.8 N/mm
Tensile Strength25 MPa transverse; 42 MPa longitudinal
Elongation at Break65% transverse; 48% longitudinal
Xenon-Lamp Aging1500 h; ΔE 3.2; no peeling
Neutral Salt Spray1500 h; ΔE 0.6; no peeling
Damp-Heat Resistance1500 h; ΔE 0.2; no delamination or peeling
Stain Resistance7%

Source: Guangzhou BV Technology Testing Co., Ltd., Report BV83647MS267, issued March 25, 2026. Results apply to the submitted sample and specified test conditions.

Typical Product Specification

ItemTypical Specification
Product FormSelf-adhesive roll film
ColorWhite
Typical Thickness700 μm or customized
Typical Width100 cm or customized
Typical Length10 m or customized
AdhesivePressure-sensitive adhesive

Installation Guidelines

  1. Inspect the substrate and repair leaks, loose fasteners, severe corrosion or unstable coatings before installation.
  2. Remove dust, oil, dirt, loose rust and sharp projections. Ensure the surface is clean and completely dry.
  3. Measure, position and pre-lay the film according to the roof or equipment geometry.
  4. Peel back the release liner gradually while pressing the film onto the substrate.
  5. Use a roller to apply even pressure and remove trapped air or voids.
  6. Use a typical overlap of 3-5 cm and seal edges or special details where project conditions require it.
  7. Inspect all seams, edges and penetrations after installation.

Installation details should be confirmed for the substrate, climate, roof geometry and service conditions. A small pilot area is recommended before large-scale application.

Reference Performance

Supplied simulation and brochure materials show strong potential reductions in roof-surface temperature, indoor temperature and cooling load. These values are reference results rather than guaranteed field performance; actual results depend on climate, substrate, ventilation, installation quality and operating conditions.

Documents Available

The English TDS, third-party test report, application procedure, product brochure and project-case materials are available on request. Contact our technical team with the substrate, dimensions and exposure conditions for a project-specific recommendation.

Reviews

There are no reviews yet.

Be the first to review “Passive Radiative Cooling Film”